Back to Components
RECP-20Public Areas

Reception, 20m2

Standard Area20
Ceiling Height2700mm

Briefing

Description
The Reception, 20m2 provides the area and amenities for three staff members to receive and check-in patients / visitors to a unit and direct them to their destination or to an adjacent waiting area. The Reception may also act as an administrative base of the unit, including organising bookings for appointments and directing phone calls to other staff, as well as controlling access. Depending on the function of unit, the Reception may also take payments.
Hours of Operation
8am to 6pm, daily (dependent on unit operating hours)
Occupancy
3 staff seated
Additional Considerations
~ Dependent on location, security glazing or shutters may be required. ~ A recessed area for front access by wheelchair users is typically required. Depending on check in requirements at Reception, a set down area for visual access only may be sufficient. ~ Provision of a hearing augmentation system may be required, particularly where security glazing if provided, and requirements are to be confirmed at project level. ~ Mobile duress coverage is to be assessed and planned at a department level and coverage is to suit local security and WHS policies and operational service requirements. ~ Adjustable height workstations may be provided in line with WHS policies and access for disabled staff working within the Reception area is to be considered. ~ CCTV monitor, intercom and door release buttons linked to entry points may be required for access control depending on location. ~ A desktop printer and labels printer may be provided as required. Printing, scanning and photocopying facilities may be consolidated with ready access from Reception to suit service requirements. ~ Swipe card access to reception may be provided to suit security requirements.

Performance Requirements

HVAC

Air Conditioning (General)

Lighting

General

Items

CodeDescriptionQtyPriorityCategoryComment
AFDPR-001.01DOOR PROTECTION: kickplate, to 300H1StandardInternal - Door 1[DWPR-001] to room side
AFDPR-006.01DOOR PROTECTION: plate, to 900H1StandardInternal - Door 1[DWPR-005] to corridor side, extent dependent on movement of beds and mobile equipment in adjacent area; to be coordinated with corridor wall protection
DOHI-013.01DOOR: hinged, 1 leaf, 900 clear opening, solid, standard vision panel1StandardInternal - Door 1[DWGL-005]
ITSE-261READER: security, access control, proximity card, wall mounted1OptionalInternal - Door 1[ITSE-038] optional